ChinaDroneRequest a quote →

Boslipo P7 Version 1400mAh 150C 4/6/8S FPV Battery

The Boslipo P7 Version is a 1400mAh 150C FPV battery available in 4S1P, 6S1P and 8S1P configurations. Each option includes an XT60 plug, with respective pack voltages of 14.8V, 22.2V and 29.6V. Maximum charging voltage is 4.2V per cell.

BosLi-poDrone battery
Capacity
1400 mAh
Nominal voltage
3.7 V
C rating
150C

Get a free quote

Product overview

The Boslipo P7 Version FPV Battery combines 1400mAh capacity with a 150C rating across three pack configurations. The 4S1P option is rated at 14.8V, the 6S1P option at 22.2V and the 8S1P option at 29.6V. Each option comes with an XT60 plug. Nominal cell voltage is 3.7V, with a maximum charging voltage of 4.2V per cell. During discharge, keep the no-load voltage above 3.5V per cell and allow at least 5 minutes of rest before recharging.

Charge the battery only when use is intended shortly afterward, keep charging attended and avoid frequent high-current charging unless necessary. Complete a charge-discharge cycle at least once per month. For long-term storage, maintain 3.85V per cell at 5-28°C; do not store at 4.2V per cell or below 3.7V per cell for extended periods. Avoid high-temperature environments during storage. Before transport on public conveyances, discharge the battery to 3.6V per cell.

Batteries & charging

Specifications

Boslipo P7 Version 1400mAh 150C 4/6/8S FPV Battery specifications
SpecificationValue & conditions
ProductBoslipo P7 Version 1400mAh 150C 4/6/8S FPV Battery
Capacity1400mAh
C rating150C
4S battery option1400mAh, 150C, 4S1P, 14.8V, XT60 plug4S1P configuration.
6S battery option1400mAh, 150C, 6S1P, 22.2V, XT60 plug6S1P configuration.
8S battery option1400mAh, 150C, 8S1P, 29.6V, XT60 plug8S1P configuration.
Nominal voltage3.7VPer cell.
Maximum charge voltageMust not exceed 4.2VPer cell during charging.
Charging supervisionNever leave the battery unattendedDuring charging.
Full-charge storage restrictionDo not store at 4.2V per cellDuring storage.
Heat exposureAvoid high-temperature environmentsDuring storage or when leaving the battery.
Rest intervalAt least 5 minutesAfter discharge, before charging.
Discharge voltage limitGreater than 3.5V; avoid deep dischargePer cell, measured with no load.
Charging timingCharge only when use is intended shortly afterwardWhen charging for use.
Fast chargingAvoid frequent fast charging unless necessaryHigh-current charging.
Maintenance cycleOne complete charge-discharge cycle at least once per monthFor cell maintenance.
Low-voltage storage restrictionNever store below 3.7V per cell for extended periodsExtended storage, per cell.
Storage voltage and temperature3.85V per cell at 5-28°CLong-term storage.
Transport voltageDischarge to 3.6V per cellTransport on public conveyances.