Boslipo P7 Version 1650mAh 150C 4/6S FPV Battery

The Boslipo P7 Version 1650mAh 150C FPV Battery comes in 4S1P 14.8V and 6S1P 22.2V configurations, each equipped with an XT60 plug. Both versions share the same capacity and C rating, with defined per-cell charging, discharge and storage requirements.

BosLi-poDrone battery
Capacity
1650 mAh
Nominal voltage
3.7 V
C rating
150C

Get a free quote

Product overview

The Boslipo P7 Version FPV Battery combines 1650mAh capacity with a 150C rating in two pack configurations. The 4S1P version is rated at 14.8V, while the 6S1P version is rated at 22.2V; both are equipped with an XT60 plug. Nominal cell voltage is 3.7V, and charging must not exceed 4.2V per cell. Keep charging supervised, charge shortly before intended use, and allow at least 5 minutes of rest after discharge before recharging. Avoid frequent high-current charging unless necessary.

Battery care requires avoiding deep discharge and keeping no-load voltage above 3.5V per cell. Complete a full charge-discharge cycle at least once per month to maintain cell health. For long-term storage, maintain 3.85V per cell at 5-28°C; do not store at 4.2V per cell or below 3.7V per cell for extended periods. Avoid leaving the battery in high-temperature environments. When transporting the battery on public conveyances, discharge it to 3.6V per cell.

Batteries & charging

Specifications

Boslipo P7 Version 1650mAh 150C 4/6S FPV Battery specifications
SpecificationValue & conditions
ProductBoslipo P7 Version 1650mAh 150C 4/6S FPV Battery
Capacity1650mAh
C rating150C
Voltage and connector14.8V; XT60 Plug4S1P configuration.
Voltage and connector22.2V; XT60 Plug6S1P configuration.
Nominal voltage3.7VPer cell.
Maximum charge voltageMust not exceed 4.2VPer cell during charging.
Charging supervisionNever leave batteries unattendedDuring charging.
Full-charge storage restrictionDo not store at 4.2V per cellDuring storage.
Heat exposureAvoid storing or leaving batteries in high-temperature environments
Rest intervalAt least 5 minutesAfter discharge, before charging.
Discharge voltage limitGreater than 3.5V; avoid deep dischargeNo-load measurement, per cell.
Charging timingCharge only when use is intended shortly afterwardBefore intended use.
Fast chargingAvoid frequent high-current (fast) chargingUnless necessary.
Charge-discharge maintenanceA complete charge-discharge cycle at least once per monthFor cell health maintenance.
Low-voltage storage restrictionNever store below 3.7V per cell for extended periodsExtended storage, per cell.
Storage voltage and temperature3.85V per cell at 5-28°CLong-term storage.
Transport voltageDischarge to 3.6V per cellWhen transporting batteries on public conveyances.