| Product type | SkyMEMS IMU688 UAV IMU tactical-grade MEMS inertial measurement unit. |
|---|
| Measurement axes | Three-axis acceleration and three-axis angular-rate sensing. |
|---|
| Construction | Capacitive technology and MEMS components in a compact aluminum housing. |
|---|
| Applications | Tactical UAS navigation and control, seekers and platform stabilization. |
|---|
| Autonomous vehicle application | Used in autonomous vehicles. |
|---|
| Interface compatibility | Compatible with the ADIS16488 interface and protocol. |
|---|
| Temperature calibration | Built-in temperature calibration and compensation algorithm. |
|---|
| Dynamic range | Gyroscope: ±450°/s; accelerometer: ±16g. |
|---|
| Accelerometer bias stability | 0.06 mg.Allan variance. |
|---|
| Gyroscope Allan bias stability | Z axis: 1.6 °/h; X and Y axes: 3.2 °/h.Allan variance; respective gyroscope axes. |
|---|
| Gyroscope fixed-temperature bias stability | Z axis: 6 °/h; X and Y axes: 12 °/h.10s average, fixed temperature within -40~+70°C; respective gyroscope axes. |
|---|
| Gyroscope bias range | Z axis: ±0.14 °/s; X and Y axes: ±0.4 °/s.Respective gyroscope axes. |
|---|
| Gyroscope full-temperature bias range | Z axis: ±0.04 °/s; X and Y axes: ±0.12 °/s.Temperature change rate ≤1℃/min; temperature range -40~+70°C; respective gyroscope axes. |
|---|
| Gyroscope startup repeatability | Startup-to-startup: Z 0.004 °/s, X/Y 0.012 °/s; day-to-day: Z 0.006 °/s, X/Y 0.018 °/s.Startup-to-startup and day-to-day measurements; respective gyroscope axes. |
|---|
| Gyroscope linear acceleration effect on bias | 0.004 °/s/g. |
|---|
| Gyroscope vibration effect on bias | Before/after: 0.004 °/s/g; before/in-run: 0.004 °/s/g.Vibration: 20~2000Hz, 6.06g; before/after and before/in-run comparisons. |
|---|
| Gyroscope scale factor | Accuracy: Z 0.6%, X/Y 1.2%; nonlinearity: Z 0.02%FS, X/Y 0.04%FS.Respective gyroscope axes. |
|---|
| Gyroscope random walk, resolution and bandwidth | - Random walk: 0.5 º/√h;
- resolution: 3.052×10−7 º/s/LSB;
- bandwidth: 200 Hz.
|
|---|
| Accelerometer fixed-temperature bias stability | 0.4 mg.10s average, fixed temperature within -40~+70°C. |
|---|
| Accelerometer bias repeatability | 1 mg. |
|---|
| Accelerometer scale factor | Accuracy: 4%; nonlinearity: 0.2%FS. |
|---|
| Accelerometer resolution and bandwidth | Resolution: 1.221×10−8 g/LSB; bandwidth: 200 Hz. |
|---|
| Communication interfaces | - SPI: 15 MHz;
- UART: 230.4 Kbps;
- CAN: 1 MHz.
One channel per interface. |
|---|
| Sampling rate | 200 Hz on each interface.SPI, UART and CAN outputs. |
|---|
| Power consumption and ripple | Power consumption: 1.5 W; peak-to-peak ripple: 100 mV. |
|---|
| Dimensions and weight | 47 × 44 × 14 mm; 50 grams. |
|---|
| Temperature ranges | Working: -40 to 70°C; storage: -45 to 75°C.Working and storage conditions, respectively. |
|---|
| Temperature test | Test temperature: -40 to 85°; actual high-temperature testing may exceed 85°. One-hour dwell at both -40° and 85°.Temperature testing; one-hour dwell at each endpoint. |
|---|
| Vibration and shock resistance | Vibration resistance: 20~2000Hz, 6.06g; shock resistance: 1000g, 0.5ms.Vibration: 20~2000Hz, 6.06g; shock duration: 0.5ms. |
|---|
| Reliability and continuous operation | MTBF: 20000 h; continuous working time: 120 h. |
|---|