ChinaDroneRequest a quote →

H200 - Firefighting Drone

The Spider-i UAV H200 Firefighting Drone is designed for aerial firefighting across mountains, grasslands, forests and specific urban areas. Equipped with four 25kg extinguishing bombs, a release mechanism, targeting dispenser and laser rangefinder, it combines autonomous operation with modular construction and a quick-release bomb deployment device.

Spider-iUAVSearch and rescue drone
Flight time
40 minutes
Weight
52 kg
Dimensions
5600 * 5600 * 980 mm (220.47″ x 220.47″ x 38.602″)
Maximum payload
100 kg

Get a free quote

Product overview

The Spider-i UAV H200 Firefighting Drone supports aerial firefighting in mountains, grasslands, forests and specific urban areas. It is equipped with a release mechanism, targeting dispenser, laser rangefinder and four 25kg fire extinguishing bombs. It can be deployed within 5 minutes, and flight paths can be changed mid-air. Autonomous operation requires minimal human intervention during flight, while the intelligent blasting control system supports timing- or height-based detonation and uses LIDAR to locate fires.

Standardized, modular parts simplify H200 maintenance. Its bomb deployment device combines 7075 aviation aluminum with carbon fiber, a quick-release design for installation and removal in one minute, and dual servo control for single or dual mode release. Unloaded flight time is 40 minutes. After a mission, the drone can continue monitoring and transmitting real-time visuals to the command center. The bombs have fully sealed, waterproof and moisture-proof construction and double-insured, explosion-proof safety fuses. These bomb specifications and the aerial platform technical parameters are theoretical values based on tests under ideal conditions; actual operation may vary with circumstances.

Fire & rescue

Specifications

H200 - Firefighting Drone specifications
SpecificationValue & conditions
ProductSpider-i UAV H200 Firefighting Drone
Applications and equipmentFirefighting in mountains, grasslands, forests and specific urban areas; equipped with a release mechanism, targeting dispenser, laser rangefinder and four 25kg fire extinguishing bombs.
Deployment and flight-path controlDeployment within 5 minutes; flight paths can be changed mid-air.
Autonomous operationAutonomous operation with minimal human intervention during flights.
Modular constructionStandardized, modular parts simplify maintenance.
Blasting controlTiming- or height-based detonation control with LIDAR fire location.
Flight time40 minutesUnloaded.
MonitoringContinued monitoring and transmission of real-time visuals to the command center.Post-mission.
Deployment device construction7075 aviation aluminum and carbon fiber.Fire extinguishing bomb deployment device.
Installation and releaseQuick-release installation and removal in one minute; dual servo control supports single or dual mode release.Fire extinguishing bomb deployment device.
Dimensions5600 * 5600 * 980 mm (220.47″ x 220.47″ x 38.602″)Aerial platform unfolded; theoretical parameters based on tests under ideal conditions.
Maximum payload100 kgAerial platform; theoretical parameters based on tests under ideal conditions.
Weight52 kgAerial platform; theoretical parameters based on tests under ideal conditions.
Maximum takeoff weight190 kgAerial platform; theoretical parameters based on tests under ideal conditions.
Operation height≤ 1000mAerial platform; theoretical parameters based on tests under ideal conditions.
Maximum altitude limit4500 mAerial platform; theoretical parameters based on tests under ideal conditions.
Caliberφ 268 mmFire-extinguishing bomb; theoretical parameters based on tests under ideal conditions.
Total bomb length600 mmFire-extinguishing bomb; theoretical parameters based on tests under ideal conditions.
Extinguishing agentWater-gel based extinguishing agent or dry powder extinguishing agentFire-extinguishing bomb; theoretical parameters based on tests under ideal conditions.
Net weight25 kgFire-extinguishing bomb; theoretical parameters based on tests under ideal conditions.
Dispersion radiusGreater than 15 mFire-extinguishing bomb; theoretical parameters based on tests under ideal conditions.
Coverage areaGreater than 200 m²Fire-extinguishing bomb; theoretical parameters based on tests under ideal conditions.
Safety radiusGreater than 40 mFire-extinguishing bomb; theoretical parameters based on tests under ideal conditions.
Height for arming releaseGreater than 15 mFire-extinguishing bomb; theoretical parameters based on tests under ideal conditions.
Bombing height15~100 mFire-extinguishing bomb; theoretical parameters based on tests under ideal conditions.
Operating environmental temperature-20℃~60℃Fire-extinguishing bomb; theoretical parameters based on tests under ideal conditions.
SealingFully sealed, waterproof and moisture-proof.Fire-extinguishing bomb; theoretical parameters based on tests under ideal conditions.
Safety fuseDouble-insured, explosion-proof.Fire-extinguishing bomb; theoretical parameters based on tests under ideal conditions.
Technical parameter qualificationTechnical parameters are theoretical values based on tests under ideal conditions; actual operation may vary with circumstances.Aerial platform and fire-extinguishing bomb technical parameters.