ChinaDroneRequest a quote →

JIOPTICS STA-M020X

The JIOPTICS STA-M020X is a miniature laser ranging module for integration into UAV pods, night vision and thermal imaging equipment. It combines a Class 1, 905nm semiconductor laser with pulse ranging over 5-2000 meters, TTL communication and a compact Φ23x47mm body.

JIOPTICSPayloads & thermal cameras
Resolution
±0.1m
Dimensions
Φ23x47 mm
Input voltage
3-5 V

Get a free quote

Product overview

The JIOPTICS STA-M020X miniature laser ranging module brings pulse distance measurement to UAV pods, night vision systems and thermal imaging equipment. Its construction incorporates a 905nm semiconductor laser with Class 1 eye safety and laser power of ≤1 mW. The module measures over 5-2000 meters, with ranging capability of 2000m for buildings and 1500m for trees. Measurement accuracy is ±1m, resolution is ±0.1m, and the ranging frequency is 1-3Hz. Its cylindrical dimensions are Φ23x47mm.

The STA-M020X uses a TTL communication interface with power, transmit, receive and reserved enable connections. Input voltage is 3-5V, with a 5V supply recommended. Operating current is ≤90mA, while standby current is ≤20mA; power consumption is ≤0.18W in standby and ≤0.55W at peak. The operating temperature range is -20°C to +55°C. Automatic output sends results after ranging finishes, while query mode returns results on command and supports single measurements only. UART IO voltage defaults to 3.3V.

Cameras & sensors

Specifications

JIOPTICS STA-M020X specifications
SpecificationValue & conditions
Manufacturer and modelJIOPTICS STA-M020X
Product type and applicationsMiniature laser ranging module for integration into UAV pods, night vision and thermal imaging equipment.
Laser wavelength and component905nm semiconductor laser
Measurement range5-2000 meters
Building ranging capability2000mBuilding target.
Tree ranging capability1500mTree target.
Measurement accuracy±1m
Resolution±0.1m
Laser safety and power≤1 mW; safe for human eyes
Laser classificationClass 1
Current consumptionOperating: ≤90mA; standby: ≤20mAOperating and standby states, respectively.
Power consumptionStandby≤0.18W; Peak≤0.55WStandby and peak states, respectively.
Operating temperature-20°C to +55°C
Storage temperature-30°C to +60°C
Input voltage3-5V5V power supply recommended.
Beam divergence angle5 mard
Ranging frequency and method1-3Hz; pulse ranging
DimensionsΦ23x47mm
Communication interface and pinsTTL; pin 1 GND, power supply −; pin 2 Vin, power supply +; pin 3 TXD, transmit data; pin 4 RXD, receive data; pin 5 ENO, reserved enable pin
Minimum interval between adjacent frames25ms600BPS communication.
Minimum interval between adjacent frames12.5ms1200BPS communication.
Minimum interval between adjacent frames6.25ms2400BPS communication.
Minimum interval between adjacent frames3.125ms4800BPS communication.
Minimum interval between adjacent frames1.56ms9600BPS communication.
Minimum interval between adjacent frames1ms (0.78ms less than 1ms, take 1ms)19200BPS communication.
Slave address configurationDefault: 0x10; 0x00 is reserved for broadcast and cannot be assigned as the slave address.New slave address takes effect after restarting the device.
Measurement result output modes
  • 0: query mode, output in response to the master's reading command;
  • 1: automatic mode, output after ranging finishes;
  • default: automatic mode
Query mode supports single measurement only.
UART IO voltage configurationSetting: 72 - 199; 0.025V/LSB
UART IO voltage formula and defaultVIO = Setting × 0.025V; default VIO = 3.3V
Communication parameter response fieldsByte 2: D4 selects data output method, D3-D0 encode baud rate; byte 3: UART IO voltage setting