JIOPTICS JIO-106425M

The Jioptics JIO-106425M 25mJ 1064nm laser photometer combines laser time-of-flight ranging with coded target irradiation. This precision photoelectric unit delivers ≥25mJ average pulse energy at 1.064μm, supports first- and last-target ranging, and provides ≥2km irradiation distance in a body weighing ≤450g.

JIOPTICSPayloads & thermal cameras
Weight
≤450g
Size
≤67.4 mm×51 mm×90 mm
Supply voltage
19.6 V ~ 25.2 V

Get a free quote

Product overview

The Jioptics JIO-106425M 25mJ 1064nm laser photometer is a precision photoelectric product that directs laser light at a target and calculates distance from laser flight time. It supports single measurements and continuous ranging at 1Hz or 5Hz, with first- and last-target ranging logic. Typical ranging capacity is ≥2000m, ranging accuracy is ±2m, and the accurate measurement rate is ≥ 98%. Power-on preparation takes ≤3s, while laser optical axis stability is ≤0.05mrad.

The unit weighs ≤450g and measures ≤67.4mm×51mm×90mm. Its 1.064μm laser delivers average pulse energy of ≥25mJ with pulse width ≤20ns and beam dispersion ≤0.5mrad. Target irradiation reaches ≥2km at a fundamental frequency of 20Hz, using precise frequency coding with encoding accuracy ≤±2.5μs. Each irradiation lasts ≥20s, with a restart interval ≤15s across 8 consecutive cycles. The supply range is 19.6V ~ 25.2V, with average power consumption ≤50W and peak consumption ≤90W. Working temperature is -40℃ ~ 55℃.

Cameras & sensorsMission payloads

Specifications

JIOPTICS JIO-106425M specifications
SpecificationValue & conditions
ProductJioptics JIO-106425M laser photometer; precision photoelectric product for laser irradiation and laser time-of-flight distance measurement
Laser wavelength1.064μm
Pulse average energy≥25mJ
Adjacent pulse energy fluctuation≤8%Within a cycle; statistics after 2 seconds of light output.
Laser beam dispersion angle≤0.5mrad
Laser optical axis stability≤0.05mrad
Pulse width≤20ns
Power-on preparation time≤3s
Ranging frequency1Hz, 5Hz, single measurement
Continuous ranging time5min(1Hz), 1min(5Hz)1Hz or 5Hz continuous ranging; automatic stop if no stop instruction is received.
Maximum continuous operating time2min5Hz operation.
Minimum range≤100m
Typical ranging capacity≥2000m
Ranging accuracy±2m
Accurate measurement rate≥ 98%
Ranging logicFirst and last target
Irradiation distance≥2km
Irradiation frequencyFundamental frequency 20Hz
CodingCoding according to system requirements; customizable coding extension
Encoding modePrecise frequency code
Encoding accuracy≤±2.5μs
Irradiation modeEach irradiation ≥20s; interval before restarting ≤15s; 8 consecutive irradiation cycles
Weight≤450g
Size≤67.4mm×51mm×90mm
Supply voltage19.6V ~ 25.2V
Standby power consumption≤4WStandby.
Average power consumption≤50W
Peak power consumption≤90W
Working temperature-40℃ ~ 55℃
Storage temperature-55℃ ~ 70℃

Related guides