Product overview
Zhuhai SV Tech Co., Ltd.’s AXR 8812 MG-D is a standard servo for model steering, control-surface movement and mechanical actuation. Its physical configuration combines a coreless motor, stainless steel gears and two bearings in a 30 × 10 × 35.2 mm envelope weighing 28.7 g. A 250 mm cable provides the connection reach. Integration requires matching the mounting holes, servo-arm connection, supply and PWM signal, with control specified at 333 Hz across an allowed supply range of 4.8–8.4 V.
At 8.4 V, the servo has a specified stall torque of 15 kg·cm and no-load speed of 0.096 s/60°, while rated torque is 5.5 kg·cm. Continuous-load selection must account for rated torque and duty cycle, and the supply needs headroom for transient current. The pulse mapping lists 1500 µs at zero degrees alongside a separate 1520 µs reference pulse, so center and usable travel depend on the controller and delivered version. Mount fabrication also requires the final installation drawing because dimensional reference points can differ.
Specifications
| Specification | Value & conditions |
|---|---|
| Product | AXR 8812 MG-D standard servo for model steering, control surfaces and mechanical actuation |
| Operating voltage | 4.8–8.4 V |
| Performance at 4.8 V |
|
| Performance at 6 V |
|
| Performance at 7.4 V |
|
| Performance at 8.4 V |
|
| Rated torque | 5.5 kg·cm @ 8.4 VSupply voltage: 8.4 V. |
| Overall dimensions | 30 × 10 × 35.2 mm |
| Weight | 28.7 g |
| Motor type | Coreless motor |
| Gear material | Stainless steel gears |
| Bearing count | 2 |
| Cable length | 250 mm |
| Control signal | PWM |
| Operating frequency | 333 Hz |
| Reference pulse width | 1520 µs |
| Pulse width and corresponding angle | 500 / 1500 / 2500 µs → -90 / 0 / 90° |
| Center and travel qualification | The 1520 µs reference pulse and 1500 µs position midpoint are both specified; center and usable travel must be established for the controller and delivered version.Controller and delivered servo version. |
| Torque limitation | Stall torque is not a continuous-load rating; continuous-duty selection must account for rated torque and duty cycle.Continuous-load operation. |
| Voltage coverage limitation | The operating-voltage range defines permitted supply voltage. |
| Mounting dimensions qualification | Drawing and specification dimensions may use different reference points; mounting parts require the final installation drawing and interface version.Mount fabrication and interface version. |