The Raytron WN2 series is an uncooled infrared thermal imaging module for industrial temperature measurement, power equipment inspection and security monitoring. It combines a 12μm detector, dedicated infrared image processing and standard shutterless correction, with three resolution options, temperature analysis tools and multiple lens and interface choices.

RaytronPayloads & thermal cameras
Resolution
384×288
Supply voltage
5 V

Get a free quote

Product overview

The Raytron WN2 series combines an in-house-developed, wafer-level-packaged 12μm detector with the second-generation Falcon 300 ASIC-ISP image processor and IMX3.0/NMX3.0 infrared image algorithms. Its vanadium oxide uncooled focal plane detector operates across an 8–14μm spectral range. Resolution options are 256×192, 384×288 and 640×512, with detector frame rates of 25/50Hz for the 256×192 configuration and 30/60Hz for the two higher-resolution configurations. Every model includes a shutterless algorithm as standard, alongside image controls for brightness, contrast, electronic zoom, polarity and pseudo-color.

Designed for industrial temperature measurement, power equipment inspection and security monitoring, the WN2 offers point, line and area temperature analysis. Measurement ranges extend from -20°C to 150°C in high-image-quality mode and 100°C to 650°C in high-range mode, with typical accuracy of ±2°C or ±2%, whichever is greater. The module measures 21×21×10.3mm and weighs less than 7g, excluding the lens and flange. Optional fixed-focus or manual-focus lenses, analog and digital video outputs, and UART, I2C and USB2.0 communication interfaces support integration.

Cameras & sensors

Specifications

Raytron WN2 specifications
SpecificationValue & conditions
Product typeRaytron WN2 series uncooled infrared thermal imaging module
DetectorVanadium oxide uncooled infrared focal plane detector; spectral range 8–14μm; pixel pitch 12μm
Detector packagingIn-house-developed 12μm wafer-level-packaged detector
Resolution, detector frame rate and lens options256×192256×192 configuration.
Resolution384×288384×288 configuration.
Resolution640×512640×512 configuration.
Detector frame rate25/50Hz256×192 configuration.
Detector frame rate30/60Hz384×288 and 640×512 configurations.
Typical power consumptionLess than 0.35W256×192 configuration; 25°C.
Typical power consumptionLess than 0.42W384×288 configuration; 25°C.
Typical power consumptionLess than 0.7W640×512 configuration; 25°C.
Optional lens focal lengths9.1/15/25mm256×192 configuration.
Optional lens focal lengths9.1/15/25/35mm384×288 configuration.
Optional lens focal lengths9.1/13.5/18/25/35/55mm640×512 configuration.
Noise-equivalent temperature difference≤40mK25°C; F#1.0; 25Hz.
Image processing hardware and algorithmsSecond-generation in-house-developed Falcon 300 ASIC-ISP chip with IMX3.0 and NMX3.0 infrared image algorithms
Shutterless correctionShutterless algorithm supplied as standardStandard across the series.
Image display controlsBrightness/contrast settings 0–100; continuous electronic zoom 1.0–8.0x in 0.1 steps; white-hot/black-hot polarity; pseudo-color; crosshair display, hide and move
Image correction and orientationNon-uniformity correction, digital noise filtering and detail enhancement; shutter correction/shutterless algorithm correction; vertical, horizontal and diagonal image mirroring
Focus optionsFixed-focus or manual-focus lensesOptional lens configurations.
Temperature measurement ranges-20°C to 150°C in high-image-quality mode; 100°C to 650°C in high-range modeHigh-image-quality mode or high-range mode, respectively.
Temperature measurement accuracy±2°C or ±2%, whichever is greaterTypical value.
Temperature analysis and dataPoint, line and area secondary analysis; information-line acquisition of temperature and other data
Supply voltage5VTypical supply voltage.
Video and communication interfaces
  • Analog video: PAL/NTSC;
  • digital video: DVP/BT656/USB2.0/MIPI;
  • serial communication: UART/I2C/USB2.0
Dimensions and weight21×21×10.3mm (W×L×H); less than 7gExcluding lens and flange.
Operating temperaturesImaging: -40°C to 80°C; temperature measurement: -20°C to 70°CImaging and temperature measurement operation, respectively.
Storage temperature and humidityStorage temperature: -45°C to 85°C; humidity: 5%–95%, non-condensingHumidity is non-condensing.
Vibration and shockVibration: 6.06g; shock: 80g@4msRandom vibration on all axes; terminal-peak sawtooth shock on three axes in six directions.