| Brand | HOAN |
|---|
| Model | JGX-0160E-4.8B |
|---|
| Product type | Maintenance-free gimbal wire rope vibration isolator |
|---|
| Base plate | 304 stainless steel; electropolished and passivated |
|---|
| Protection mechanism | Mechanical overtravel limiter and secondary HNBR elastomeric snubber ring |
|---|
| Maintenance and inspection | No maintenance required; lifetime-sealed design; visual inspection every 500 flight hours |
|---|
| Design service life | Greater than 15 yearsContinuous rated load at 25 degrees Celsius ambient. |
|---|
| Operating temperature | -50 to +150 degrees CelsiusContinuous operation. |
|---|
| Corrosion resistance | 1000+ hours; offshore/marine certifiedNeutral salt spray, ASTM B117. |
|---|
| Damping efficiency | Greater than 88 percentAt resonance frequency 10–2500 Hz. |
|---|
| Natural frequency | 8–12 HzAt rated load. |
|---|
| Maximum shock input | 50 G peak acceleration11 ms duration; MIL-STD-810H Method 516.8 compliant. |
|---|
| Vertical load performance | - Maximum static load: 4.8 N;
- maximum deformation: 9.7 mm;
- vibration stiffness: 30 KN/m;
- impact stiffness: 19 KN/m
Vertical loading. |
|---|
| 45° directional load performance | - Maximum static load: 3.6 N;
- maximum deformation: 14.7 mm;
- vibration stiffness: 17 KN/m;
- impact stiffness: 9.5 KN/m
45° directional loading. |
|---|
| Lateral load performance | - Maximum static load: 2.5 N;
- maximum deformation: 10.7 mm;
- vibration stiffness: 11 KN/m;
- impact stiffness: 11 KN/m
Lateral loading. |
|---|
| Mounting configuration | Type-B mounting with dual mounting bars for medium-format professional cinema cameras |
|---|
| Primary damping mechanism | Internal dry friction damping in the wire rope isolator elementNormal operational vibration. |
|---|
| Secondary protection activation | Rigid stainless steel overtravel limiter engages to prevent further deflectionIsolator displacement exceeds 85% of maximum travel. |
|---|
| Snubber function | HNBR snubber ring absorbs residual impact energy and provides a soft stopDuring secondary protection engagement. |
|---|
| Factory pretension and heat setting | Pretensioned to 120% of maximum rated static load; heat-set at 350°C for 4 hours |
|---|
| Fastener interface treatment | DIN 127B helical spring lock washers and pre-applied medium-strength anaerobic threadlocker |
|---|
| Recommended payload weight | 2.4–3.4 N; 50%–70% of the 4.8 N rated loadFor optimal engagement of the primary and secondary protection stages. |
|---|
| Lateral stiffness symmetry | Equal lateral stiffness in both directionsType-B dual-bar mounting configuration. |
|---|
| Mounting fasteners and torque | M4 fasteners; 3.0 N·mInstallation using a calibrated torque wrench. |
|---|
| Certifications | ISO 9001:2015, CE, RoHS, REACH |
|---|
| Applications | Professional cinema and broadcast gimbals; border patrol and coast guard UAVs; agriculture and crop monitoring; power line and pipeline inspection; atmospheric research and weather monitoring; tactical ISR; offshore oil and gas inspection |
|---|