Product overview
The BWSENSING BWA500C is a single-axis shaft-angle sensor for aircraft control-surface measurement, wind-tunnel testing and industrial inclination applications. Its enclosure uses anodized magnesium-aluminum alloy, an aviation connector and four M4 screws for mounting. Overall dimensions are L60 × W59 × H29 mm excluding the aviation connector, with weight ≤300 g and IP67 ingress protection. The stated product dimensions are subject to the actual physical product. Other applications include platform leveling, construction machinery, dam monitoring, slope disaster prevention, foundation-pit inclination measurement and tower tilt monitoring.
The BWA500C measures Y-axis angles over ±180°, with counterclockwise rotation positive and clockwise rotation negative. It provides 0.01° resolution, output rates ≤500 Hz, automatic calibration and selectable RS232, RS485 or TTL output. The serial communication rate is adjustable from 2400 to 921600. Accuracy is 0.03° without mounting error when the non-measurement X-axis angle is 0°. With mounting error, accuracy is 0.1° when X remains within ±50° and the measurement Y-axis angle remains within ±40°. Operating temperature is -40°C to +85°C, and storage temperature is -55°C to +100°C.
Specifications
| Specification | Value & conditions |
|---|---|
| Product type | BWA500C series shaft-angle sensor |
| Connector | Aviation connector |
| Ingress protection | IP67 |
| Housing material | Anodized magnesium-aluminum alloy |
| Mounting | Four M4 screws |
| Measurement range | ±180°Y-axis measurement; counterclockwise rotation is positive and clockwise rotation is negative. |
| Resolution | 0.01° |
| Accuracy without mounting error | 0.03°No mounting error; non-measurement X-axis angle is 0°. |
| Accuracy with mounting error | 0.1°With mounting error; non-measurement X-axis angle within ±50° and measurement Y-axis angle within ±40°. |
| Output axes | Single axis (Y) |
| Output rate | ≤500Hz |
| Serial communication rate | 2400–921600, adjustable |
| Output interface options | RS232 / RS485 / TTLInterface output selected from the listed options. |
| Calibration | Automatic calibration |
| Operating temperature | -40°C to +85°C |
| Storage temperature | -55°C to +100°C |
| Overall dimensions | L60 × W59 × H29 mmExcluding the aviation connector. |
| Weight | ≤300 g |
| Product size qualification | L60 × W59 × H29 mmDimensions subject to the actual physical product. |
| Applications | Aircraft control-surface measurement; wind-tunnel testing; dam monitoring; slope disaster prevention; construction machinery; platform leveling; foundation-pit inclination measurement; tower tilt monitoring |
Request a quote for BWA500C
Send your application, destination country and expected quantity to the ChinaDrone team. We can discuss product selection, configuration and sourcing from China.
Submit your procurement requirements ↗No account needed. A model number is optional. Your enquiry is handled by ChinaDrone.