The BWSENSING BW-SAS-2134 is a compact inertial measurement unit providing acceleration measurement and calculated attitude-angle output. It features temperature calibration and compensation across -40 ℃ to +85 ℃, UART/SPI output options, and a default RS-232 interface. The 20 g unit measures 38×24×11.5 mm and consumes 0.3 W.

BWSENSINGDrone flight controller
Supply voltage
5±0.5 VDC
Weight
20 g
Dimensions
38×24×11.5 mm

Get a free quote

Product overview

The BWSENSING BW-SAS-2134 series inertial measurement unit combines acceleration measurement with calculated attitude-angle output. Its accelerometer has a ±8 g measurement range, with ±16 g available as a customization. Pitch and roll accuracy are each 0.2° RMS under static conditions and 2° RMS under dynamic conditions. Built-in temperature calibration and compensation algorithms maintain accuracy across -40 ℃ to +85 ℃. Accelerometer bandwidth is 88.6 Hz at 200 Hz, with cross-coupling of 200 ppm.

The unit measures 38×24×11.5 mm and weighs 20 g. It operates from a 5±0.5 VDC supply and consumes 0.3 W. Output options include UART through RS-232 or LVTTL, as well as SPI; RS-232 is the default interface, while the BW-SAS-2134-LVTTL model provides LVTTL. Accelerometer bias stability is 0.02 mg by Allan variance, 0.2 mg with a 10 s average at 25 ℃, and 1 mg with a 10 s average across -40 ℃ to +85 ℃ at a temperature change rate of 1 ℃/min.

Flight control & navigationCameras & sensors

Specifications

BWSENSING BW-SAS-2134 specifications
SpecificationValue & conditions
Product typeBW-SAS-2134 series inertial measurement unit
Temperature compensationBuilt-in temperature calibration and compensation algorithms maintain accuracy across -40 ℃ to +85 ℃.
Output interfacesUART (RS-232 or LVTTL) / SPI
Attitude outputSupports calculated attitude-angle output
Default interfaceRS-232Standard BW-SAS-2134 configuration.
Optional interfaceLVTTLBW-SAS-2134-LVTTL model.
Accelerometer measurement range±8 g
Custom accelerometer measurement range±16 gCustomized accelerometer range.
Accelerometer bias stability0.02 mgAllan variance.
Accelerometer bias stability0.2 mg10 s average at 25 ℃, room temperature.
Accelerometer bias stability1 mg10 s average over -40 ℃ to +85 ℃ with a temperature change rate of 1 ℃/min.
Accelerometer scale-factor nonlinearity200 ppm±1 g.
Accelerometer cross-coupling200 ppm
Accelerometer bandwidth88.6 HzAt 200 Hz.
Pitch angle accuracy0.2°Static, RMS.
Pitch angle accuracy2°Dynamic, RMS.
Roll angle accuracy0.2°Static, RMS.
Roll angle accuracy2°Dynamic, RMS.
Supply voltage5±0.5 VDC
Power consumption0.3 W
Dimensions38×24×11.5 mm