| Integrated sensors | 60x hybrid zoom camera, thermal imaging camera and laser rangefinder |
|---|
| Dimensions and weight | 96.4 x 96 x 147mm; 620g |
|---|
| Operating voltage | 20 ~ 53 VDC |
|---|
| Power consumption | 10.5W average with ranging off; 55 W stalled with ranging onAverage with ranging off; stalled with ranging on. |
|---|
| Gimbal construction and mounting | Upright or inverted mounting |
|---|
| Gimbal stabilization | Non-orthogonal three-axis mechanical stabilization; stabilization accuracy ±0.01° |
|---|
| Controlled rotation and maximum control speed | - Pitch: -175° to +105°;
- roll: ±50°;
- yaw: ±360° continuous;
- maximum control speed: ±200°/s
|
|---|
| Target positioning accuracy at 105m | Horizontal error: 1.8m; height error: 0.7mHorizontal distance 105m; relative height 75m. Measured against known ground coordinates from a multirotor UAV with dual-antenna RTK positioning; reference results depend on aircraft positioning and heading accuracy, mounting alignment, slant range, measurement-line slope and air quality. |
|---|
| Target positioning accuracy at 513m | Horizontal error: 17.4m; height error: 6.7mHorizontal distance 513m; relative height 119m. Measured against known ground coordinates from a multirotor UAV with dual-antenna RTK positioning; reference results depend on aircraft positioning and heading accuracy, mounting alignment, slant range, measurement-line slope and air quality. |
|---|
| Target positioning accuracy at 1003m | Horizontal error: 33.8m; height error: 13.7mHorizontal distance 1003m; relative height 246m. Measured against known ground coordinates from a multirotor UAV with dual-antenna RTK positioning; reference results depend on aircraft positioning and heading accuracy, mounting alignment, slant range, measurement-line slope and air quality. |
|---|
| Focal length | 5.5~54.7mm; equivalent focal length: 37.2~370.5mmZoom camera. |
|---|
| Aperture | F/1.8~f/2.6Zoom camera. |
|---|
| Horizontal field of view | 53.9° to 5.8°Zoom camera. |
|---|
| Vertical field of view | 31.9° to 3.3°Zoom camera. |
|---|
| Target detection distances | - Pedestrian: 18862m;
- small vehicle: 57844m;
- large vehicle: 123232m
Zoom camera; Johnson criteria. Critical target dimensions: pedestrian 0.75m, small vehicle 2.3m, large vehicle 4.9m. |
|---|
| Target recognition distances | - Pedestrian: 330m;
- small vehicle: 434m;
- large vehicle: 925m
Zoom camera; EN62676-4:2015. Reference target dimensions: pedestrian 1.8x0.5m, small vehicle 4.2x1.8m, large vehicle 6.0x4.0m. |
|---|
| Target recognition distances | - Pedestrian: 4716m;
- small vehicle: 14461m;
- large vehicle: 30808m
Zoom camera; Johnson criteria. Critical target dimensions: pedestrian 0.75m, small vehicle 2.3m, large vehicle 4.9m. |
|---|
| Target identification distances | - Pedestrian: 165m;
- small vehicle: 217m;
- large vehicle: 462m
Zoom camera; EN62676-4:2015. Reference target dimensions: pedestrian 1.8x0.5m, small vehicle 4.2x1.8m, large vehicle 6.0x4.0m. |
|---|
| Target identification distances | - Pedestrian: 2358m;
- small vehicle: 7231m;
- large vehicle: 15404m
Zoom camera; Johnson criteria. Critical target dimensions: pedestrian 0.75m, small vehicle 2.3m, large vehicle 4.9m. |
|---|
| Focal length | 19mm; equivalent focal length: 83.6mmThermal imaging camera. |
|---|
| Aperture | F/1.0Thermal imaging camera. |
|---|
| Horizontal field of view | 22.9°Thermal imaging camera. |
|---|
| Vertical field of view | 18.4°Thermal imaging camera. |
|---|
| Diagonal field of view | 29.0°Thermal imaging camera. |
|---|
| Target detection distances | - Pedestrian: 750m;
- small vehicle: 2300m;
- large vehicle: 4900m
Thermal imaging camera; Johnson criteria. Critical target dimensions: pedestrian 0.75m, small vehicle 2.3m, large vehicle 4.9m. |
|---|
| Target recognition distances | - Pedestrian: 188m;
- small vehicle: 575m;
- large vehicle: 1225m
Thermal imaging camera. |
|---|
| AI detection and tracking | Multi-target pedestrian and vehicle detection with continuous tracking of a selected targetOptional AICore installed. |
|---|
| Control interfaces and protocols | Network, serial and S.BUS control; proprietary protocol and MAVLink support |
|---|
| Operating environment | - Operating temperature: -20°C to 50°C;
- storage temperature: -40°C to 60°C;
- operating humidity: ≤85%RH, non-condensing
|
|---|
| Thermal lens exposure limits | Do not point the lens at intense energy sources such as the sun, lava or lasers. Observed target temperature must remain below 600°C to prevent irreversible camera damage.Thermal imaging camera. |
|---|