ChinaDroneRequest a quote →

Swiwin SW300Pro

The Swiwin SW300Pro is an aviation-kerosene turbojet engine delivering 30kg of thrust. Measuring 132mm in diameter and 331.4mm long, it weighs 2560g and combines a brushless starting motor with electronic control of fuel delivery, ignition timing and motor operation.

SwiwinMotors, ESCs & propellers
Thrust
30 kg
Weight
2.56 kg

Get a free quote

Product overview

The Swiwin SW300Pro turbojet engine delivers 30kg of thrust in a package measuring 132mm in diameter and 331.4mm in length, with a weight of 2560g. It runs on aviation kerosene, with fuel consumption of ≤820g/min and a lubricating oil proportion of 3%~5%. Its speed range is 38000~98000, with an idle speed of 38000 RPM. The rated exhaust maximum temperature is 750℃, and the maintenance cycle is 25H.

The engine uses a high-power brushless starting motor and electronic engine control. Its ECU processes engine sensor data to control fuel amount, ignition timing and the brushless motor. Fault diagnosis provides an alarm when a failure occurs and stores the relevant fault code in internal memory for troubleshooting and repair. Control and connection equipment comprises a power line, signal line, GSU, ECU(V4), Festo filter and switch valve.

Motors & ESCs

Specifications

Swiwin SW300Pro specifications
SpecificationValue & conditions
ProductSwiwin SW300Pro turbojet engine
Thrust30kg
Diameter132mm
Length331.4mm
Weight2560g
Speed range38000~98000
Idle RPM38000
Rated exhaust maximum temperature750℃
Fuel consumption≤820g/min
FuelAviation kerosene
Lubricating oil3%~5%
Maintenance cycle25H
Pump voltage0.5-1.2V
RPM ACC25
Eject time0.4S
RPM start-up ramp100
RPM DEC25
Ejection low voltage4V
Pump start-up ramp3
Idle RPM range38000~98000
Run voltage5V
Control and connection equipmentPower line, signal line, GSU, ECU(V4), Festo filter and switch valve
Starting motorHigh-power brushless starting motor
ECU control functionsProcesses engine sensor data and controls fuel amount, ignition timing and the brushless motor
Fault diagnosisIssues a fault alarm and stores the relevant fault code in internal memory