The RYDBATT LP-6252144-12S2P-40.8V21.6Ah is an industrial UAV lithium-ion drone battery pack with 881Wh energy, matched cells and CANopen telemetry. Its 12S2P construction supports 30A continuous discharge and 130A pulses for 10 seconds, with layered BMS protection and seven independent hardware fuses.

RYDBATTDrone battery
Capacity
21.6Ah typ. / 20.5Ah min
Nominal voltage
40.8 V
Continuous discharge
30 A (sustained cruise / hover / payload)
Weight
≈4.1 kg (with protective case)
Dimensions
186.9 × 167.5 × 120.25 mm (±1.0 mm), maximum

Get a free quote

Product overview

The RYDBATT LP-6252144-12S2P-40.8V21.6Ah drone battery pack provides lithium-ion power for industrial UAV operations including spray passes and LiDAR scanning. Its 12-series, 2-parallel construction uses matched grade-A high-energy cells, delivering 881Wh at a nominal 40.8V with 21.6Ah typical capacity and 20.5Ah minimum capacity. Continuous discharge is 30A for sustained cruise, hover and payload operation, with 130A pulses for 10 seconds during takeoff, gusts or emergencies. The pack weighs approximately 4.1 kg with its protective case and measures a maximum 186.9 × 167.5 × 120.25 mm, with ±1.0mm tolerance.

CANopen communication at 125 kbit/s carries cell voltage and temperature, state of charge and fault events. The BMS combines two-tier over-voltage protection, staged over-current protection, under-voltage lockout, over-temperature protection and passive balancing. Seven MCU-independent fuses protect the charge and discharge paths. Charging operates at 0–50°C, while discharge operates at -20–60°C; charging below 0°C is inhibited. A deep-discharge lock at 2.8V per cell requires a charger to wake the pack. Supplied documentation includes a UN38.3 test summary and MSDS baseline, with UL/IEC/ISO documentation prepared per project and destination market.

Batteries & charging

Specifications

RYDBATT LP-6252144-12S2P-40.8V21.6Ah specifications
SpecificationValue & conditions
Model and configurationRYDBATT LP-6252144-12S2P-40.8V21.6Ah; 12S2P (12 series × 2 parallel)
ConstructionIndustrial UAV lithium-ion battery pack built with matched grade-A high-energy cells.
Nominal voltage40.8V
Capacity21.6Ah typ. / 20.5Ah min
Energy881Wh (≈215 Wh/kg pack-level)Pack-level energy density.
Charge voltage50.4V (CC/CV, cut-off ≤0.02C)CC/CV charging; cut-off ≤0.02C.
Discharge cut-off30V (pack level)Pack level.
Continuous discharge30A (sustained cruise / hover / payload)Sustained cruise / hover / payload.
Pulse discharge130A / 10s (takeoff, gust, emergency)10s pulse for takeoff, gust or emergency.
Pack impedance≤60mΩ (AC 1kHz, fresh pack)AC 1kHz, fresh pack.
Voltage sagLess than 5% from 100% to 5% SoCFrom 100% to 5% SoC.
CommunicationCANopen 125 kbit/s reporting cell voltage/temperature, SoC and fault events; object dictionary and protocol documentation shared under NDA.
BMS protectionTwo-tier OVP, staged OCP, UVP lockout, OTP, balancing
Hardware fuses7 independent fuses: 2×30A charge path + 5×40A discharge path (MCU-independent)MCU-independent.
BalancingPassive, starts ≥30mV delta, closes to ≤10mV
Cycle lifeGreater than 100 cycles to 80% retention (1C discharge)1C discharge.
Weight≈4.1 kg (with protective case)With protective case.
Dimensions186.9 × 167.5 × 120.25 mm (±1.0mm), maximumMaximum dimensions; ±1.0mm tolerance.
Operating temperatureCharge 0–50°C / Discharge -20–60°CCharging and discharging respectively.
Supplied documentationUN38.3 test summary and MSDS baseline supplied with the pack; UL/IEC/ISO documentation prepared per project and destination market.UL/IEC/ISO documentation prepared per project and destination market.
TraceabilityFile-numbered: cell lot → BMS firmware → batch test data
Cell over-voltage protectionTwo-tier: 4.23V alert → 4.265V cutoff, release at 4.10V
Pack over-voltage protection50.76V backup cutoff (guards single-cell sensing fault)Backup cutoff guarding single-cell sensing fault.
Discharge over-current protectionStaged: 60A/5min alert → 145A/10s hard cutoffDischarge; 5min alert stage and 10s hard-cutoff stage.
Charge over-current protection30A then 60A stagedCharging.
Under-voltage protectionDeep-discharge lock at 2.8V/cell, wake-on-charger onlyWake-on-charger only after deep-discharge lock.
Thermal protection and idle leakageCharging below 0°C inhibited; full over-temperature protection with auto-sleep (300–500µA idle)Charging below 0°C inhibited; 300–500µA during idle auto-sleep.
Typical flight envelope20–45 minutes endurance at 1.2–2.5kW average draw; scenarios include hovering in wind, spray passes, LiDAR scanning and vertical takeoff.Mid-size industrial multirotors drawing 1.2–2.5kW average; depending on payload and wind.
Capacity retention≥85% after 28 days storage at 25±5°C28 days storage at 25±5°C.
Payload scenariosHovering in wind, spray passes, LiDAR scanning and vertical takeoff