| Model and configuration | RYDBATT LP-6252144-12S2P-40.8V21.6Ah; 12S2P (12 series × 2 parallel) |
|---|
| Construction | Industrial UAV lithium-ion battery pack built with matched grade-A high-energy cells. |
|---|
| Nominal voltage | 40.8V |
|---|
| Capacity | 21.6Ah typ. / 20.5Ah min |
|---|
| Energy | 881Wh (≈215 Wh/kg pack-level)Pack-level energy density. |
|---|
| Charge voltage | 50.4V (CC/CV, cut-off ≤0.02C)CC/CV charging; cut-off ≤0.02C. |
|---|
| Discharge cut-off | 30V (pack level)Pack level. |
|---|
| Continuous discharge | 30A (sustained cruise / hover / payload)Sustained cruise / hover / payload. |
|---|
| Pulse discharge | 130A / 10s (takeoff, gust, emergency)10s pulse for takeoff, gust or emergency. |
|---|
| Pack impedance | ≤60mΩ (AC 1kHz, fresh pack)AC 1kHz, fresh pack. |
|---|
| Voltage sag | Less than 5% from 100% to 5% SoCFrom 100% to 5% SoC. |
|---|
| Communication | CANopen 125 kbit/s reporting cell voltage/temperature, SoC and fault events; object dictionary and protocol documentation shared under NDA. |
|---|
| BMS protection | Two-tier OVP, staged OCP, UVP lockout, OTP, balancing |
|---|
| Hardware fuses | 7 independent fuses: 2×30A charge path + 5×40A discharge path (MCU-independent)MCU-independent. |
|---|
| Balancing | Passive, starts ≥30mV delta, closes to ≤10mV |
|---|
| Cycle life | Greater than 100 cycles to 80% retention (1C discharge)1C discharge. |
|---|
| Weight | ≈4.1 kg (with protective case)With protective case. |
|---|
| Dimensions | 186.9 × 167.5 × 120.25 mm (±1.0mm), maximumMaximum dimensions; ±1.0mm tolerance. |
|---|
| Operating temperature | Charge 0–50°C / Discharge -20–60°CCharging and discharging respectively. |
|---|
| Supplied documentation | UN38.3 test summary and MSDS baseline supplied with the pack; UL/IEC/ISO documentation prepared per project and destination market.UL/IEC/ISO documentation prepared per project and destination market. |
|---|
| Traceability | File-numbered: cell lot → BMS firmware → batch test data |
|---|
| Cell over-voltage protection | Two-tier: 4.23V alert → 4.265V cutoff, release at 4.10V |
|---|
| Pack over-voltage protection | 50.76V backup cutoff (guards single-cell sensing fault)Backup cutoff guarding single-cell sensing fault. |
|---|
| Discharge over-current protection | Staged: 60A/5min alert → 145A/10s hard cutoffDischarge; 5min alert stage and 10s hard-cutoff stage. |
|---|
| Charge over-current protection | 30A then 60A stagedCharging. |
|---|
| Under-voltage protection | Deep-discharge lock at 2.8V/cell, wake-on-charger onlyWake-on-charger only after deep-discharge lock. |
|---|
| Thermal protection and idle leakage | Charging below 0°C inhibited; full over-temperature protection with auto-sleep (300–500µA idle)Charging below 0°C inhibited; 300–500µA during idle auto-sleep. |
|---|
| Typical flight envelope | 20–45 minutes endurance at 1.2–2.5kW average draw; scenarios include hovering in wind, spray passes, LiDAR scanning and vertical takeoff.Mid-size industrial multirotors drawing 1.2–2.5kW average; depending on payload and wind. |
|---|
| Capacity retention | ≥85% after 28 days storage at 25±5°C28 days storage at 25±5°C. |
|---|
| Payload scenarios | Hovering in wind, spray passes, LiDAR scanning and vertical takeoff |
|---|