| Manufacturer, model and product type | The Levane Power HLF12K-D60-H1000 is a 12 kW DC/DC power converter for tethered UAVs, underwater vehicles and underwater robots. |
|---|
| UAV applications | An onboard power supply for heavy-lift tethered UAVs used for emergency lighting, disaster relief and emergency communications.For heavy-lift tethered UAV applications. |
|---|
| Matching tether cable length | Approximately 100–200 m. |
|---|
| Input voltage range | 800–1000 Vdc.Rated input: 950 Vdc. |
|---|
| Rated and maximum output power | Rated: 12000 W; maximum: 12500 W. |
|---|
| Maximum efficiency | ≥ 97%.Rated input of 950 Vdc at half load. |
|---|
| Voltage regulation | Voltage regulation accuracy: ≤ ±1%; line regulation and load regulation: each ≤ ±1%. |
|---|
| Output ripple and noise | ≤ ±2% Vo.Full load; 20 MHz bandwidth; test terminals connected in parallel with a 10 µF electrolytic capacitor and a 0.1 µF film capacitor. |
|---|
| Maximum input current | 14 A.800 Vdc input and full-load output. |
|---|
| Temperature coefficient | ±0.02%/°C. |
|---|
| Output timing | Output rise time: ≤ 500 ms; startup output delay: ≤ 5 s.The startup output delay applies at rated input. |
|---|
| Overshoot | ΔV: ≤ ±5%.During switching on and off. |
|---|
| Dynamic response recovery time | ≤ 2 ms.25°C, with load changes of 25%–50%–25% or 50%–75%–50%. |
|---|
| Communications | CAN communications, customizable to protocol requirements. |
|---|
| Input undervoltage protection | - Trigger: 770–790 Vdc;
- recovery voltage: ≤ 800 Vdc;
- hysteresis: greater than 10 V.
|
|---|
| Input overvoltage protection | - Trigger: 1030–1070 Vdc;
- recovery voltage: ≥ 1000 Vdc;
- hysteresis: greater than 10 V.
|
|---|
| Input reverse-polarity protection | No damage under reverse-polarity connection.750 Vdc reverse-polarity input test. |
|---|
| Output overvoltage protection | 53–55 Vdc.Automatic recovery. |
|---|
| Output overcurrent protection | 270–300 A.Automatic recovery. |
|---|
| Output short-circuit protection | Sustains a prolonged short circuit with automatic recovery. |
|---|
| Overtemperature protection | Protection temperature: 70°C; recovery temperature: 60°C.Internal bottom-case temperature; output derates during overtemperature. |
|---|
| Operating and storage temperatures | Operating: −40°C to +45°C; storage: −40°C to +85°C. |
|---|
| Relative humidity | ≤ 95%.Non-condensing at 40°C ±2°C. |
|---|
| Altitude | 0–2000 m. |
|---|
| Cooling | Baseplate-contact or liquid cooling; fluorinated liquid or transformer oil can provide cooling. |
|---|
| Protective treatment | Moisture, mildew and salt-mist protection for humid outdoor and salt-mist environments.Meets GB/T 4797.6 Table 9 requirements. |
|---|
| System noise | ≤ 55 dB(A). |
|---|
| Electrical insulation | Dielectric withstand: input to output, 2500 Vdc/2 mA/1 min; input to housing, 2000 Vdc/2 mA/1 min; output to housing, 1000 Vdc/2 mA/1 min. Insulation resistance: ≥ 10 MΩ at 500 Vdc.Dielectric tests require no flashover or breakdown. Insulation resistance applies at normal atmospheric pressure and 90% humidity, between input and output, input and housing, and output and housing. |
|---|
| Reliability and flammability | - Predicted MTBF: ≥ 100K hours. PCB flammability: V-0;
- insulated cable: GB/T 18380.12-2008;
- other insulating materials: V-1.
MTBF is predicted at 25°C, rated input and full-load output using the MIL-HDBK-217F Notice 2 stress method. Flammability provisions meet GB4943.1-2011 requirements. |
|---|
| Dimensions and net weight | Heat sink: 277 mm × 202 mm × 70 mm (±1 mm); product net weight: approximately 3.2 kg.Dimensions refer to the heat sink, with ±1 mm tolerance. |
|---|