| Input voltage range | 680 ~ 800 VdcRated input: 750Vdc. |
|---|
| Output voltage | Rated: 50 Vdc; range: 46–51 Vdc |
|---|
| Output current | Rated: 240A; maximum: 260A |
|---|
| Voltage regulation accuracy | ≤ ±1%; line and load regulation each ≤ ±1% |
|---|
| Output ripple and noise | ≤ ±2% Vo20MHz bandwidth; 10uF electrolytic and 0.1uF film capacitors connected across the test terminals; full load. |
|---|
| Maximum input current | 16 A800Vdc input; full-load output. |
|---|
| Temperature coefficient | ±0.02 %/°C |
|---|
| Output startup timing | Output rise time: ≤ 500 ms; startup output delay: ≤ 5 sStartup output delay applies at rated input. |
|---|
| Output overshoot | ΔV: ≤ ±5%During switching on and off. |
|---|
| Dynamic response recovery time | ≤ 2 ms25%–50%–25% or 50%–75%–50% load changes at 25°C. |
|---|
| Communication | CAN; protocol customization available |
|---|
| Input voltage protection thresholds | Undervoltage: 670 ~ 680 Vdc; overvoltage: 820 ~ 830 VdcUndervoltage recovery: ≥ 680 Vdc; overvoltage recovery: ≤ 810 Vdc; hysteresis greater than 10V for each. |
|---|
| Input reverse-polarity protection | No damage with reversed polarity750Vdc reverse-polarity input test. |
|---|
| Output overvoltage protection | 53 ~ 55 VdcAutomatic recovery. |
|---|
| Output overcurrent protection | 270 ~ 300 AAutomatic recovery. |
|---|
| Output short-circuit protection | Sustained short-circuit protectionAutomatic recovery. |
|---|
| Overtemperature protection | 70°CInternal baseplate temperature; recovery at 60°C; output derates above the temperature threshold. |
|---|
| Temperature ranges | Operating: -40°C ~ +45°C; storage: -40°C ~ +85°C |
|---|
| Relative humidity | ≤ 95%Non-condensing at 40°C ±2°C. |
|---|
| Altitude | 0 ~ 2000 m |
|---|
| Cooling | Baseplate contact or liquid cooling; fluorinated fluid or transformer oil cooling |
|---|
| Protective treatment | Moisture, mildew and salt-mist protectionMeets GB/T 4797.6 Table 9 requirements for outdoor humid and salt-mist environments. |
|---|
| System noise | ≤ 55 dB(A) |
|---|
| Dielectric strength | - Input to output: 2500Vdc/2mA/1min;
- input to enclosure: 2000Vdc/2mA/1min;
- output to enclosure: 1000Vdc/2mA/1min
No arcing or dielectric breakdown. |
|---|
| Insulation resistance | ≥ 10MΩ @ 500VdcNormal atmospheric pressure; 90% humidity; input to output/enclosure and output to enclosure. |
|---|
| Mean time between failures | ≥ 100K Hours25°C, rated input and full-load output; predicted using the MIL-HDBK-217F Notice2 stress method. |
|---|
| Flame resistance | - PCB: V-0;
- insulated cables: GB/T 18380.12-2008;
- other insulating materials: V-1
Meets GB4943.1-2011 requirements. |
|---|
| Heatsink dimensions | 277mm x 202mm x 70mmDimensional tolerance: ±1mm. |
|---|
| Net weight | Approximately 3.2 KG |
|---|
| Tether cable length | Approximately 100m - 200mMatched tether cable. |
|---|