ChinaDroneRequest a quote →

Levane Power HLF12K-D50-H800

The Levane Power HLF12K-D50-H800 is an onboard DC/DC power converter for heavy-load tethered UAVs, underwater vehicles and underwater robots. It converts 680–800 Vdc input to a rated 50 Vdc output at 240A, with CAN communication, baseplate or liquid cooling, and electrical and thermal protection.

Levane PowerDrone battery
Net weight
Approximately 3.2 KG

Get a free quote

Product overview

The Levane Power HLF12K-D50-H800 is an onboard DC/DC power converter developed for heavy-load tethered UAVs, underwater vehicles and underwater robots. Its UAV applications include emergency lighting, disaster relief and emergency communications. The converter accepts 680–800 Vdc, with a rated input of 750Vdc, and delivers a rated 50 Vdc output at 240A. CAN communication supports protocol customization, while the matched tether cable length is approximately 100–200m.

The module weighs approximately 3.2 KG and has heatsink dimensions of 277mm x 202mm x 70mm, with a ±1mm tolerance. Cooling uses baseplate contact or coolant, including fluorinated fluid or transformer oil. Protective treatment resists moisture, mildew and salt mist. Electrical protection covers input undervoltage, overvoltage and reversed polarity, plus output overvoltage, overcurrent and sustained short circuits. Overtemperature protection activates at an internal baseplate temperature of 70°C, reduces output and recovers at 60°C. The operating temperature range is -40°C to +45°C.

Batteries & charging

Specifications

Levane Power HLF12K-D50-H800 specifications
SpecificationValue & conditions
Input voltage range680 ~ 800 VdcRated input: 750Vdc.
Output voltageRated: 50 Vdc; range: 46–51 Vdc
Output currentRated: 240A; maximum: 260A
Voltage regulation accuracy≤ ±1%; line and load regulation each ≤ ±1%
Output ripple and noise≤ ±2% Vo20MHz bandwidth; 10uF electrolytic and 0.1uF film capacitors connected across the test terminals; full load.
Maximum input current16 A800Vdc input; full-load output.
Temperature coefficient±0.02 %/°C
Output startup timingOutput rise time: ≤ 500 ms; startup output delay: ≤ 5 sStartup output delay applies at rated input.
Output overshootΔV: ≤ ±5%During switching on and off.
Dynamic response recovery time≤ 2 ms25%–50%–25% or 50%–75%–50% load changes at 25°C.
CommunicationCAN; protocol customization available
Input voltage protection thresholdsUndervoltage: 670 ~ 680 Vdc; overvoltage: 820 ~ 830 VdcUndervoltage recovery: ≥ 680 Vdc; overvoltage recovery: ≤ 810 Vdc; hysteresis greater than 10V for each.
Input reverse-polarity protectionNo damage with reversed polarity750Vdc reverse-polarity input test.
Output overvoltage protection53 ~ 55 VdcAutomatic recovery.
Output overcurrent protection270 ~ 300 AAutomatic recovery.
Output short-circuit protectionSustained short-circuit protectionAutomatic recovery.
Overtemperature protection70°CInternal baseplate temperature; recovery at 60°C; output derates above the temperature threshold.
Temperature rangesOperating: -40°C ~ +45°C; storage: -40°C ~ +85°C
Relative humidity≤ 95%Non-condensing at 40°C ±2°C.
Altitude0 ~ 2000 m
CoolingBaseplate contact or liquid cooling; fluorinated fluid or transformer oil cooling
Protective treatmentMoisture, mildew and salt-mist protectionMeets GB/T 4797.6 Table 9 requirements for outdoor humid and salt-mist environments.
System noise≤ 55 dB(A)
Dielectric strength
  • Input to output: 2500Vdc/2mA/1min;
  • input to enclosure: 2000Vdc/2mA/1min;
  • output to enclosure: 1000Vdc/2mA/1min
No arcing or dielectric breakdown.
Insulation resistance≥ 10MΩ @ 500VdcNormal atmospheric pressure; 90% humidity; input to output/enclosure and output to enclosure.
Mean time between failures≥ 100K Hours25°C, rated input and full-load output; predicted using the MIL-HDBK-217F Notice2 stress method.
Flame resistance
  • PCB: V-0;
  • insulated cables: GB/T 18380.12-2008;
  • other insulating materials: V-1
Meets GB4943.1-2011 requirements.
Heatsink dimensions277mm x 202mm x 70mmDimensional tolerance: ±1mm.
Net weightApproximately 3.2 KG
Tether cable lengthApproximately 100m - 200mMatched tether cable.