| Product identity and application | Levane Power HLF12K-D48-H1000 DC/DC power converter for underwater vehicles and underwater robots. |
|---|
| Input voltage | 800–1000 Vdc; rated input: 950 Vdc. |
|---|
| Output voltage | Rated output: 48 Vdc; range: 44–49 Vdc. |
|---|
| Output current | Rated: 250 A; maximum: 260 A. |
|---|
| Maximum efficiency | ≥97%.Rated input of 950 Vdc, at half load. |
|---|
| Voltage regulation | Voltage regulation accuracy: ≤±1%; line and load regulation: each ≤±1%. |
|---|
| Output ripple and noise | ≤±2% Vo.Full load; 20 MHz bandwidth; 10 uF electrolytic and 0.1 uF film capacitors connected across the test terminals. |
|---|
| Maximum input current | 14 A.800 Vdc input, full-load output. |
|---|
| Temperature coefficient | ±0.02%/°C. |
|---|
| Output timing | Output rise time: ≤500 ms; startup output delay: ≤5 s.Startup output delay applies at rated input. |
|---|
| Output overshoot | ΔV: ≤±5%.During switching on and off. |
|---|
| Dynamic response recovery time | ≤2 ms.25°C; load changes of 25%–50%–25% or 50%–75%–50%. |
|---|
| Communications | CAN; customizable to protocol requirements. |
|---|
| Input undervoltage protection | - Trigger: 770–790 Vdc;
- recovery voltage: ≤800 Vdc;
- hysteresis: greater than 10 V.
|
|---|
| Input overvoltage protection | - Trigger: 1030–1070 Vdc;
- recovery voltage: ≥1000 Vdc;
- hysteresis: greater than 10 V.
|
|---|
| Input reverse-polarity protection | No damage from reversed input polarity.750 Vdc reverse-polarity input test. |
|---|
| Output overvoltage protection | 51–53 Vdc; automatic recovery. |
|---|
| Output overcurrent protection | 270–300 A; automatic recovery. |
|---|
| Output short-circuit protection | Supports sustained output short circuit with automatic recovery. |
|---|
| Overtemperature protection | Protection at 70°C; recovery at 60°C.Internal baseplate temperature. |
|---|
| Temperature ranges | Operating: −40°C to +45°C; storage: −40°C to +85°C. |
|---|
| Humidity and altitude | Relative humidity: ≤95%; altitude: 0–2000 m.Relative humidity applies at 40°C ±2°C, non-condensing. |
|---|
| Cooling | Baseplate-contact or liquid cooling; fluorinated fluid or transformer oil cooling. |
|---|
| Protective treatment | Protection against moisture, mold and salt spray; meets GB/T 4797.6 Table 9 requirements for humid outdoor salt-spray environments. |
|---|
| System noise | ≤55 dB(A). |
|---|
| Dielectric strength | Input to output: 2500 Vdc; input to housing: 2000 Vdc; output to housing: 1000 Vdc; no flashover or breakdown.Each dielectric withstand test lasts 1 minute at 2 mA. |
|---|
| Insulation resistance | ≥10 MΩ.500 Vdc, normal atmospheric pressure, 90% humidity; input to output/housing and output to housing. |
|---|
| Mean time between failures | ≥100K hours.25°C, rated input, full-load output; predicted using the MIL-HDBK-217F Notice2 stress method. |
|---|
| Flammability ratings | PCB: V-0; insulated cables: GB/T 18380.12-2008; other insulating materials: V-1; meets GB4943.1-2011 requirements. |
|---|
| Net weight and matching tether length | Matching tether cable length: approximately 100–200 m.Cable length refers to the matching tether cable. |
|---|