ChinaDroneRequest a quote →

3.7V 160mAh Li-ion polymer battery pack(1S1P of FLP-402025)

The FLYPOWER 3.7V 160mAh Li-ion polymer battery pack (1S1P of FLP-402025) combines an FLP-402025 cell with CC/CV charging and overcharge, overdischarge and discharge overcurrent protection. Measuring 4.1mm × 20.2mm × 27.5mm and weighing approximately 3.5g, it supports a maximum continuous discharge current of 160mA.

Guangpeng Fly-PowerDrone battery
Nominal capacity
160 mAh
Nominal voltage
3.7 V
Weight
Approx. 3.5g

Get a free quote

Product overview

The FLYPOWER 3.7V 160mAh Li-ion polymer battery pack (1S1P of FLP-402025) uses a 3.7V 160mAh FLP-402025 cell in a single-series arrangement. The pack measures 4.1mm × 20.2mm × 27.5mm and weighs approximately 3.5g. It uses CC/CV charging, with a standard constant charge current of 0.2C (32mA) and a constant charge voltage of 4.2V per cell. Maximum continuous discharge current is 160mA, with a discharge cutoff voltage of 2.75V.

Charging operates from 0 to 45ºC, while discharging operates from -20 to 60ºC. Overcharge protection detects 4.250±0.050V and releases at 4.150±0.050V, with a detection delay of 1.0±0.5 seconds. Overdischarge protection detects 2.75±0.08V and releases at 3.00±0.10V, with a 100±50mS delay. Discharge overcurrent protection has a 1000mA threshold and a 10.0±5.0mS delay. At 40–60% charge, storage temperatures are -20 to 60ºC for less than 30 days and -20 to 45ºC for less than 90 days.

Batteries & charging

Specifications

3.7V 160mAh Li-ion polymer battery pack(1S1P of FLP-402025) specifications
SpecificationValue & conditions
ProductFLYPOWER 3.7V 160mAh Li-ion polymer battery pack (1S1P of FLP-402025)
Cell3.7V 160mAh FLP-402025
Battery pack method1S of FLP-402025
Nominal voltage3.7V
Nominal capacity160mAh
Charge methodCC/CV
Standard chargeConstant charge current: 0.2C(32mA); constant charge voltage: 4.2V/CellStandard charge.
Maximum continuous discharge current160mA
Discharge cutoff voltage2.75V
Battery dimensions4.1mm * 20.2mm*27.5mm
WeightApprox. 3.5g
Overcharge detection voltage4.250±0.050VOvercharge protection.
Overcharge release voltage4.150±0.050VOvercharge protection.
Overcharge detection delay1.0±0.5SOvercharge protection.
Overdischarge detection voltage2.75±0.08VOverdischarge protection.
Overdischarge release voltage3.00±0.10VOverdischarge protection.
Overdischarge detection delay100±50mSOverdischarge protection.
Overcurrent threshold1000mADischarge overcurrent protection.
Overcurrent delay10.0±5.0mSDischarge overcurrent protection.
Operating temperature0 ~ 45ºCCharging.
Operating temperature-20 ~ 60ºCDischarging.
Storage ambient temperature-20~60ºCStorage at 40–60% charge for less than 30 days.
Storage ambient temperature-20~45ºCStorage at 40–60% charge for less than 90 days.