ChinaDroneRequest a quote →

Multi-rotor UAV magnetic amplifier system

The GTK (Shenzhen) Technology Co., Ltd. Multi-rotor UAV magnetic amplifier system combines magnetic measurement and ultra-low-altitude terrestrial gamma spectroscopy for uranium, thorium and potassium isotope detection. It features shared acquisition with aeromagnetic data, DJI eport v2 data collection support and a 670ML crystal.

GTKPayloads & thermal cameras

Get a free quote

Product overview

The GTK (Shenzhen) Technology Co., Ltd. Multi-rotor UAV magnetic amplifier system combines magnetic measurement with ultra-low-altitude terrestrial gamma spectroscopy for uranium, thorium and potassium isotope detection. Its acquisition architecture integrates magnetic and playback data acquisition, shares one acquisition system with aeromagnetic acquisition, and supports DJI eport v2 data collection. The system incorporates a 670ML crystal and a data collector with ADC accuracy of greater than 24 bits. Energy resolution is better than 10% at the Cs137-662KeV peak.

Magnetic measurement covers 1000nT-100000nT with reading resolution of ≤0.0001nT and gradient tolerance of greater than 100nT/cm. Ground static noise is ≤0.01nT, while dynamic noise after compensation is ≤0.08nT. Fluxgate sensitivity is ≤0.02nT/√Hz in the 0.1- 100Hz frequency band using the power spectrum, and fluxgate frequency domain noise is ≤ 10pT rms/√Hz. The total weight of the magnetic discharge system is 4900g.

Cameras & sensorsMission payloads

Specifications

Multi-rotor UAV magnetic amplifier system specifications
SpecificationValue & conditions
ManufacturerGTK (Shenzhen) Technology Co., Ltd.
ProductMulti-rotor UAV magnetic amplifier system
Reading resolution≤0.0001nT
Range1000nT-100000nT
Ground static noise level≤0.01nTGround static measurement.
Dynamic noise≤0.08nTAfter compensation.
Gradient toleranceGreater than 100nT/cm
Fluxgate sensitivity≤0.02nT/√Hz0.1- 100Hz frequency band, power spectrum.
Fluxgate frequency domain noise≤ 10pT rms/√Hz
DJI data collection supportSupports DJI eport v2 data collection
Data collector ADC accuracyGreater than 24 bits
Data acquisition integrationIntegrated magnetic and playback data acquisition
Crystal size670ML crystal
Acquisition systemShares one acquisition system with aeromagnetic acquisition
Gamma spectroscopy functionTerrestrial gamma spectroscopy for uranium, thorium and potassium element isotope detectionUltra-low-altitude operation.
Energy resolutionBetter than 10%Cs137-662KeV peak.
Total weight of magnetic discharge system4900g