ChinaDroneRequest a quote →

Gesai WF-1000S60-24K

The Gesai GS WF-1000S60-24K is a regulated tethered UAV power supply system for industrial drones and special equipment. It combines isolated DC-DC conversion, an 800-1000V DC input, a regulated 60V/480A output and 24KW continuous power, with XT60 input and M8 output terminals.

GesaiDrone battery
Weight
9500 grams
Input voltage
800-1000 V DC

Get a free quote

Product overview

The Gesai GS WF-1000S60-24K supplies continuous power to industrial drones and special equipment, including long-endurance drones used for police surveillance, border patrol and emergency communications. Its isolated DC-DC converter converts 1000V DC to 60V DC with a rated output power of 24KW. The system accepts an 800-1000V DC input and provides a regulated 60V/480A output. Measuring 370*223*127mm and weighing 9500 grams, it incorporates an XT60 input terminal and an M8 output terminal.

Construction requirements cover V-0 PCB flame retardancy under GB4943.1-2011, insulated cable flame retardancy under GB/T 18380.12-2008, and V-1 performance for other insulating materials under GB4943.1-2011. Internal circuit boards, connectors and circuits require protection against moisture, mildew and salt spray, with salt spray resistance meeting Table 9 of GB/T 4797.6. The system has an IP65 protection requirement; water must not accumulate on top of its enclosure. System noise must not exceed 60 dB(A), and MTBF is greater than 100K hour.

Batteries & charging

Specifications

Gesai WF-1000S60-24K specifications
SpecificationValue & conditions
Brand and modelGesai GS WF-1000S60-24K
Product typeHigh-power regulated tethered power supply system
External dimensions370*223*127mm
Input voltage800-1000V DC
Regulated output60V/480A
Continuous power24KW
Input terminalXT60
Output terminalM8
Weight9500 grams
Isolated DC-DC conversionIsolated conversion to 60V DC; rated output power 24KW1000V DC input.
ApplicationsContinuous power for industrial drones and special equipment
Long-endurance drone usesPolice surveillance, border patrol and emergency communications
PCB flame retardancy requirementV-0 under GB4943.1-2011
Insulated cable flame retardancy requirementGB/T 18380.12-2008
Other insulating materials flame retardancy requirementV-1 under GB4943.1-2011
System noise requirementNo more than 60 dB(A)
ReliabilityMTBF greater than 100K hour
Protection rating requirementIP65No water should accumulate on top of the power supply enclosure.
Environmental protection requirementsMoisture, mildew and salt spray protectionPrinted circuit boards, connectors and other internal circuits.
Salt spray resistance requirementTable 9 in GB/T 4797.6Outdoor humid and salt spray environments.

Related guides