ChinaDroneRequest a quote →

ANAXIN ANX-1612-4200-YK

The ANAXIN ANX-1612-4200-YK is a 16S intelligent UAV battery built with 21700 ternary lithium-ion cells. This 59.2V pack combines voltage balancing, integrated charge indicators, audible and visual alarms, CAN and serial interfaces, Bluetooth connectivity and continuous battery logging for power delivery and battery monitoring.

AnaxinDrone battery

Get a free quote

Product overview

The ANAXIN ANX-1612-4200-YK is an intelligent battery for UAV use, built with 21700-format ternary lithium-ion cells in a 16S configuration. The pack weighs 14.5kg and has a nominal voltage of 59.2V, with an operating voltage range of 48–67.2V. Its charge voltage limit is 67.2V, and maximum charging current is 50A. Maximum continuous discharge current is 200A, with a maximum peak discharge current of 300A. Operating ambient temperatures are -10°C to +60°C during discharge and 0°C to +45°C during charging.

Built-in charge indicators, four red warning LEDs and a buzzer provide battery status and alarm feedback. A self-test runs at each startup; a large cell voltage difference triggers 10 simultaneous flashes of the red LEDs and an audible warning that balancing maintenance is required. The battery uses voltage balancing. When the battery is severely imbalanced, users can manually activate its intelligent maintenance function for balancing. Combined audible and visual alarms indicate overvoltage, low voltage, charging overcurrent and overtemperature. When powered on without electrical equipment connected, the battery automatically shuts down after 3 minutes to conserve charge.

CAN and serial communication interfaces, together with Bluetooth, provide access to real-time battery information including individual cell voltage, total voltage, current, state of charge, temperature and cycle count. The management system continuously records cell voltage, current, battery temperature, balancing activity, cycle count and abnormal-event counts. Host-computer software supports retrieval and analysis by date and time. For a quick charge-level reading while the battery is switched off, a short button press illuminates the green indicators for 3 seconds before they turn off.

Batteries & charging

Specifications

ANAXIN ANX-1612-4200-YK specifications
SpecificationValue & conditions
ManufacturerZhengzhou Anaxin Electronic Technology Co., Ltd
ModelANAXIN ANX-1612-4200-YK
Product typeUAV intelligent battery
Cell chemistry and formatTernary lithium-ion, 21700 cells
Series configuration16S
Nominal pack voltage59.2V
Charge voltage limit67.2V
Maximum charging current50A
Maximum continuous discharge current200A
Maximum peak discharge current300A
Operating voltage range48–67.2V
Overvoltage alarm / recovery thresholdsTYP. 4.30V / 4.25V
Low-voltage alarm / recovery thresholdsTYP. 2.90V / 2.95V
Overtemperature alarm / recovery thresholdsTYP. 75°C / 70°C
Balancing methodVoltage balancing
Operating ambient temperature-10°C to +60°CDuring discharge.
Operating ambient temperature0°C to +45°CDuring charging.
Wired communicationCAN / serial
Wireless communicationBluetooth
Battery pack weight14.5kg
Integrated charge indicatorBuilt-in indicator lights display the current battery charge level.
Startup self-test and imbalance warningThe battery performs a startup self-test. A large cell voltage difference triggers 10 simultaneous flashes of four red LEDs and a buzzer alarm, indicating that balancing maintenance is required.At each power-on; when the cell voltage difference is large.
Automatic shutdownAutomatically shuts down after 3 minutes to conserve charge.Powered on with no electrical equipment connected.
Manual balancing maintenanceA manually activated intelligent maintenance function balances the battery.When the battery is severely imbalanced.
Abnormal-condition alarmsCombined buzzer and LED warnings indicate abnormalities including overvoltage, low voltage, charging overcurrent and overtemperature.
Real-time battery informationReal-time information includes individual cell voltage, total voltage, current, state of charge, temperature and cycle count.Through the battery communication interface or Bluetooth.
Continuous logging and software accessThe management system continuously monitors and records cell voltage, current, battery temperature, balancing records, cycle count and abnormal-event counts. Host-computer software supports queries and analysis by date and time.
Charge-level queryGreen LEDs display the charge level for 3 seconds, then turn off.With the battery switched off, after a short button press.